Thermo Scientific Revco General-Purpose Laboratory Freezer ULT3030-D, (-30 C) - 29.2 Cu. Ft.

Thermo Scientific Revco General-Purpose Laboratory Freezer ULT3030-D, (-30 C) - 29.2 Cu. Ft.
Thermo Scientific Revco General-Purpose Laboratory Freezer ULT3030-D, (-30 C) - 29.2 Cu. Ft.
SKU: ULT3030-D
Mfg Number:
Capacity:
29.2 Cu. Ft.
Temperature:
-30 C
Dimensions:
77.5"H x 35.5"D x 34"W
Defrost:
Auto
Door:
Solid Door
Retail: $8,672.00 Price: $6,689.89
 
You Save: $1,982.11 (22.9%)

    Quantity:
    Availability: In Stock Usually ships In 2-3 Weeks

    Medical Freezers (to -25C) - 29.2 Cu. Ft. Revco General-Purpose Laboratory Freezer - Upright - Thermo Scientific ULT3030-D

    Thermo Scientific Revco General-Purpose Laboratory Freezer ULT3030-D, (-30 C) - 29.2 Cu. Ft. for storing reagents, pharmaceuticals, biologicals, and other laboratory materials at temperatures as cold as -30 degree C. Available in a variety of cabinet styles to accommodate the space restrictions in any laboratory.

    Heavy-duty refrigeration system is equipped with a hermetically sealed compressor. High-density, CFC-free urethane foam insulation minimizes the effects of ambient temperature fluctuations, reducing operating costs. Positive forced air circulation preserves temperature uniformity throughout the cabinet, while the directional airflow assures quick recovery following door openings. Automatic defrost feature maintains optimum cooling capacity. Automatic condensate removal eliminates the need for drain lines.

    Volume826 L (29.2 Cu. Ft.)
    Temperature Range-30 C
    DefrostAuto
    No. of Doors1
    Door TypeSolid
    CabinetUpright
    No. of Shelves4
    Interior Dimensions147.3H x 73.7D x 76.2W cm. (58"H x 29"D x 30"W)
    Exterior Dimensions196.9H x 90.2D x 86.4W cm. (77.5"H x 35.5"D x 34"W)
    Electrical208/230V, 60Hz
    Amps/ Breaker12/15
    Shipping Weight202 kg. (445 lbs.)

    Thermo Scientific Revco General-Purpose Laboratory Freezer ULT3030-D Features:

    • IntrLogic Microprocessor Control
      This unit features enhanced digital electronic technology designed to simplify operation and deliver greater accuracy
      Pre-set -30 C operation
      Icon-based controls and displays include graphic references for universal operation
      Setpoint security with key- operated triple-position master switch controls power to all systems for added safety
      Audible/visual warnings for overtemperature, undertemperature and power failure, with visual status reports on critical functions
      Graphic thermometer confirms proper operation at-a-glance, shows normal, high or low temperature condition; steady green for normal, flashing top bar for overtemperature, flashing bulb for undertemperature
      Advanced defrost sensor manages the defrost cycle, minimizing trace amounts of frost build-up to maintain refrigeration coil efficiency
      Enlarged digital display, resolution to within 0.1 C, improves visibility
      Alarm silence, ringback and automatic reset functions
      Push button alarm test verifies sensor continuity
      Battery backup assures control panel function during power failure
      Remote alarm contacts
    • Cabinet Construction and Inventory System
      High-density, CFC-free urethane foam insulation protects cabinet from ambient temperature fluctuations and minimizes operating costs
      Positive, forced-air circulation maintains temperature uniformity at all shelf levels
      Directional air flow assures quick recovery after door openings
      Solid door with keyed door lock for added security
      Self-closing doors close against closed-cell peripheral gasket
      Door locking provision
      Full-length door handle(s)
      Epoxy-coated, open wire shelves, adjustable in 1" (25 mm) increments; no tools required
      Adjustable leveling feet standard; optional casters are available
      Scratch resistant painted interior and exterior finish for easy cleaning
      1" (25 mm) access port
    • Refrigeration System
      Heavy duty, industrial-grade, hermetically sealed compressors
      Automatic defrost maintains optimum cooling capacity
      Automatic condensate removal; no drain lines required
    • Optional Accessories
      Voltage safeguard, free standing
      Built-in 6" (152 mm), 7-day circular chart recorder
      Access port 1" (25 mm) diameter
      Stainless steel interior and exterior surfaces
      2" (50 mm) casters
      Additional shelves
    • Power Failure Icon Illuminated when main power is interrupted
    • Service Required Illuminated when controller is in programming mode, or if simulated warm or cold conditions fail to occur during alarm test function
    • Touchpad Data Entry Increases or decreases setpoint values in programming mode
    • Audible Alarm: Audible and visual indicators are activated in the event of warm, cold or power loss conditions. Mute will silence audible alarm with 6 minute ring back interval; display remains flashing
    • Touchpad Scan Changes main display; also used to access various programming and service functions (alarm mute, recall 6 minutes).
    • Alarm Test: Pressing "up" and "scan" buttons creates simulated overtemperature and undertemperature condition and activates audible and visual alarms; display flashes momentarily when test is complete
    • Battery Backup: Continuous charge provides full alarm function in case of power failure. Low Battery Alarm Illuminated when the alarm system battery backup charge is low
    • Door Ajar Illuminated when door is left open and alarm is in "active" mode (not available on sliding glass door cabinet)